Patient monitors YR02170 // YR02172 are advanced medical devices designed for accurate patient monitoring. Featuring multi-channel display capability and a large-font interface, these monitors ensure easy and fast reading of critical data. They analyze the ST segment and arrhythmias while offering drug dose calculations with titration tables. Thanks to the OxyCRG's digital signage, monitoring with apnea alarms, and their ability to connect to both wired and wireless networks, these monitors are ideal for use in a variety of clinical environments. With a plug-in rechargeable battery and NIBP overpressure protection devices, they ensure reliable and continuous performance. Explore the capacity of these monitors and request an automatic quote via Kalstein Plus without delay.Features
| Model | YR02170 | YR02171 | YR02172 | |
| ECG | Power Mode | 5 Leads(RA,LA,LL,RL,V) | ||
| Connection method | I, II, III,AVR,AVL,AVF,V | |||
| Lead Mode | 3 Threads (RA,LA,LL) | |||
| Connection method | I, II, III | |||
| Waveform | 1 bsp | |||
| Gain | x250, x500, x1000, x2000 | |||
| HR Range | Adult: 15~300bpm | |||
| Neo/Ped | 15~350bpm | |||
| Accuracy | ±1% or ±1bpm | |||
| Resolution | 1bpm | |||
| Sensitivity | >200(uVp-p) | |||
| Differential Input Impedance | ≥5MΩ | |||
| ST Segment Monitoring Range | ||||
| Measuring range | -2.0~+2.0mV | |||
| Measurement accuracy | -0.8mV~+0.8mV | |||
| Heart rate | Measuring range | 0~350bpm | 20~300bpm | |
| Accuracy | ±1bpm | |||
| Resolution | 1bpm | |||
| Sensitivity | >200UVp-p | |||
| Breathing | Measurement method | Impedance between R-F(RA-LL) | ||
| Differential Input Impedance | >2.5MΩ | |||
| Measurement impedance range | 0.3~3.0 MΩ | |||
| Baseline Impedance Range | 200~4000Ω | |||
| Bandwidth | 0.1~2.5Hz | |||
| Rate of resp. Response rate | Adult: 2~120BrPM | |||
| Neo/Ped | 2~150BrPM | 0~150BrPM | ||
| Resolution | 1 BrPM | |||
| Accuracy | ±2 BrPM | |||
| Alarm | 10~40S | |||
| NIBP | Method | Oscillometric | ||
| How it works | Manual/Auto/STAT | |||
| Measurement interval in AUTO mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |||
| Measurement period in STAT mode | 5 min | |||
| Pulse frequency range | 40~240bpm | |||
| Alarm Type | SYS, DIA, AVERAGE | |||
| Resolution | ||||
| Pressure | 1mmHg | |||
| Accuracy | Maximum Average Error: 5mmHg | |||
| Maximum standard deviation | 8mmHg | |||
| SPO2 | Display | SPO2 number, capacitance waveform, pulse | ||
| Measuring range | 0~100% | |||
| Resolution | 1% | |||
| Accuracy | 70~100% (±2%) | |||
| Alarm system | Audio-video alarm | |||
| Pulse Rate Range | 0~300bpm | |||
| TEMP | Channel | 2 | ||
| Measurement and alarm range | 0~50ºC | |||
| Resolution | 0.1ºC | |||
| Accuracy | 0.1ºC | |||
| Refresh interval | Approximately 1 second | |||
| Average Time Constant | <10 seconds | |||
What our Clients are Saying
The organic reviews not hoax.
Meet Us At
06 - 07 - 08 DECEMBER 2024 International Convention City Bashundhara (ICCB) - Dhaka - Bangladesh
8 to 10 May 2025 Bangabandhu International Conference Center- BICC Dhaka on
19th to 21st December. 2025 Bangabandhu International Conference Center- BICC Dhaka.
Let's profit together! We are looking for distributors in your area.