The YR02173 Bedside Monitor is a versatile and indispensable device in the medical setting, offering a wide range of built-in features for vital signs tracking. Equipped with a 12.1-inch touchscreen, this equipment allows a clear and precise display of data. It supports comprehensive monitoring with 5-lead ECG, RESP, temperature (single channel), SpO2, NIBP, HR, and many other critical parameters for diagnosis and patient monitoring. A perfect choice for demanding healthcare professionals who require optimal reliability and performance in their daily operations.

Features

  • 12.1-inch touchscreen
  • 5-lead ECG, RESP, temperature (single channel)
  • SpO2, PNI, FC, versatile mounting options

Technical specifications

ModelYR02173
ECGLead Mode5 Threads (RA, LA, LL, RL, V)
Connection methodI, II, III,AVR,AVL,AVF,V
Lead Mode3 Lead (RA,LA,LL)
Connection methodI, II, III
Waveform1 bsp
Gain1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto.
HR RangeAdult: 15~300bpm
Neo/Ped15~350bpm
Accuracy±1% or ±1bpm
Resolution1bpm
Sensitivity200(uVp-p)
Differential Input Impedance≥5MΩ
ST Segment Monitoring Range
Measuring range-2.0~+2.0mV
Measurement accuracy-0.8mV~+0.8mV
Heart rateMeasuring range15~300bpm
Accuracy±1bpm
Resolution1bpm
Sensitivity200UVp-p
BreathingMethodImpedance between R-F(RA-LL)
Differential Input Impedance>2.5MΩ
Measurement impedance range0.3~3.0 MΩ
Baseline Impedance Range200~4000Ω
Bandwidth0.1~2.5Hz
Respiration rateAdult: 2~120BrPM
Neo/Ped0~150BrPM
Resolution1 BrPM
Accuracy±2 BrPM
Alarm10~40S
NIBPMethodOscillometric
FashionManual/Auto/STAT
Measurement interval in AUTO mode1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Measurement period in STAT mode5 min
Pulse Rate Range40~240bpm
Alarm TypeSYS, DIA, MEAN
Resolution
Pressure1mmHg
AccuracyMaximum Average Error: 5mmHg
Maximum Standard Deviation8mmHg
SPO2DisplaySPO2 number, capacitance waveform, pulse
Measuring range0~100%
Resolution1%
Accuracy60~100% (±2%)
Alarm systemAudio-video alarm
Pulse frequency range0~300bpm
TEMPChannel2
Measurement and alarm range0~50ºC
Resolution0.1ºC
Accuracy0.1ºC
Refresh intervalAbout 1 second.
Average Time Constant<10 Second.

What our Clients are Saying

The organic reviews not hoax.


Meet Us At


Bangla Med Expo

06 - 07 - 08 DECEMBER 2024 International Convention City Bashundhara (ICCB) - Dhaka - Bangladesh

Meditex Bangladesh Expo 2025

8 to 10 May 2025 Bangabandhu International Conference Center- BICC Dhaka on

Dhaka International Diagnostic Medical Equipment Expo 2025

19th to 21st December. 2025 Bangabandhu International Conference Center- BICC Dhaka.

Become Our Distributor

Let's profit together! We are looking for distributors in your area.

WhatsApp Chat

© Medico-Bangladesh. All Rights Reserved