The Multi-Parameter Patient Monitor YR02178/YR02179 is an advanced solution for patient monitoring in hospital settings, particularly in the operating room and intensive care units. Featuring an LCD display and a semi-modular setup, this monitor offers a wide range of standard vital parameters such as ECG, SPO2, temperature (SPECT), non-invasive blood pressure (NIBP), respiration (RESP), and heart rate/pulse (PR/HR). Its design allows for the integration of additional options, such as a touchscreen, Masimo/Nellcor SpO2, dual IBP measurement, among others, to meet the specific needs of healthcare professionals.
| Model | YR02178 | YR02179 | |
| ECG | Lead Mode | 5 Threads (RA, LA, LL, RL, V) | |
| Connection method | I, II, III,AVR,AVL,AVF,V | ||
| Lead Mode | 3 Lead (RA,LA,LL) | ||
| Connection method | I, II, III | ||
| Waveform | 1 bsp | ||
| Gain | x250, x500, x1000, x2000 | ||
| HR Range | Adult: 15~300bpm | ||
| Neo/Ped | 15~350bpm | ||
| Accuracy | ±1% or ±1bpm | ||
| Resolution | 1bpm | ||
| Sensitivity | 200(uVp-p) | ||
| Differential Input Impedance | ≥5MΩ | ||
| ST Segment Monitoring Range | |||
| Measuring range | -2.0~+2.0mV | ||
| Measurement accuracy | -0.8mV~+0.8mV | ||
| Heart rate | Measuring range | 40~240bpm | |
| Accuracy | ±3bpm | ||
| Resolution | 1bpm | ||
| Sensitivity | 200UVp-p | ||
| Breathing | Method | Impedance between R-F(RA-LL) | |
| Differential Input Impedance | >2.5MΩ | ||
| Measurement impedance range | 0.3~3.0 MΩ | ||
| Baseline Impedance Range | 200~4000Ω | ||
| Bandwidth | 0.1~2.5Hz | ||
| Respiration rate | Adult: 7~120BrPM | ||
| Neo/Ped | 7~150BrPM | ||
| Resolution | 1 BrPM | ||
| Accuracy | ±2 BrPM | ||
| Alarm | 10~40S | ||
| NIBP | Method | Oscillometric | |
| Fashion | Manual/Auto/STAT | ||
| Measurement interval in AUTO mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | ||
| Measurement period in STAT mode | 5 min | ||
| Pulse Rate Range | 40~240bpm | ||
| Alarm Type | SYS, DIA, MEAN | ||
| Resolution | |||
| Pressure | 1mmHg | ||
| Accuracy | Maximum Average Error: 5mmHg | ||
| Maximum Standard Deviation | 8mmHg | ||
| SPO2 | Display | SPO2 number, capacitance waveform, pulse | |
| Measuring range | 0~100% | ||
| Resolution | 1% | ||
| Accuracy | 70~99% (±2%) | ||
| Alarm system | Audio-video alarm | ||
| Pulse frequency range | 0~300bpm | ||
| TEMP | Channel | 2 | |
| Measurement and alarm range | 0~50ºC | ||
| Resolution | 0.1ºC | ||
| Accuracy | 0.1ºC | ||
| Refresh interval | about 1 second. | ||
| Average Time Constant | <10 Second. | ||
What our Clients are Saying
The organic reviews not hoax.